12.3 Programming Commands
Programming a Phone Number to Dial
Command Explanation Format
01 Phone #1 RED button 01<phone number>#
02 Phone #2 RED button 02<phone number>#
03 Phone #3 RED button 03<phone number>#
04 Phone #1 BLACK button 04<phone number>#
05 Phone #2 BLACK button 05<phone number>#
06 Phone #3 BLACK button 06<phone number>#
07 Loss of power phone number 07<phone number>#
08 Loss of battery phone number 08<phone number>#
09 PAS Fault phone number 09<phone number>#
Programming for Hot Line (Ring-Down)
NOTES: HOT LINE (aka ring-down) – If the IA4100 is connected to a private line, automatic ring-down or “hotline,” all
phone number locations 01 through 09 must be cleared, with 99Ý99# so no phone number will be dialed.
Call the extension or phone number of CB Unit, after the RFA tone:
12583# programming mode
99Ý99#
defaults phone / full reset
57# trains the phone on the local loop
5000# programs the phone for ringdown
Ý#
hang up and exit programming
If messages are required see section 3.
The maximum number of digits including Ý and # is 45.
A one-second pause when entering phone num bers is the Ý (star) symbol.