GU-139-Tpage 18 of 33
IA4100
Administrator Guide
Programming Commands (continued)
Programming Outputs
Command Explanation Format Default
11 Auxiliary output 1 11<active time># 91
12 Auxiliary output 2 12<active time># 01
13 Auxiliary output 3 13<active time># 01
NOTES: Active Time Values
00 = disabled
01 - 60 = 1 to 60 seconds
61 - 90 = 1 minute to 30 minutes
91 = until the end of the call
92 = until trigger on input 2
Recording Messages
Call the extension or phone number of CB Unit, after the RFA tone:
Programming Recordings
Command Explanation Format
12583# programming mode
21 Message recording #1 21<record message>#
22 Message recording #2 22<record message>#
23 Message recording #3 23<record message>#
24 Message recording #4 24<record message>#
25 Message recording #5 25<record message>#
26 Message recording #6 26<record message>#
27 Message recording #7 27<record message>#
28 Message recording #8 28<record message>#
29 Message recording #9 29<record message>#
Ý#
hang up and exit programming
NOTES:
RECORDING STEPS
1. Enter Command 21-29 followed by the # key
2. Wait for the beep
3. Recite your message
4. Enter # to conrm completion
5. The message will be played back for approval
6. Repeat steps 1-4 if your message is not ac
ceptable
7. Enter the # key to terminate playback (21-29
Programming Mode only).
Maximum message length is 30 seconds.
To listen to a recorded message, dial ÝÝ <Command 21-29>#
For example: To listen to recording number 4 (Command 24): ÝÝ 24#
Message volume level can be changed with programming Command 67.