LS1000 VoIP Speakerphone
Administrator Guide
page 49 of 54 GU-164-B
Code Blue
259 Hedcor Street Holland, MI 49423 USA 800.205.7186 www.codeblue.com
Mode Number
Secondary-Flash Mode
1
Single - 60 FPM
2
Single - 60 FPM
3
Single - 60 FPM
4
Single - 150 FPM
5
Single - 150 FPM
6
Single - 150 FPM
7
Single - 375 FPM
8
Single - 375 FPM
9
Single - 375 FPM
10
Neobe - 75
11
Neobe - 75
12
Neobe - 75
13
Neobe - 150
14
Neobe - 150
15
Neobe - 150
16
Double - 125
17
Double - 125
18
Double - 125
19
Double - 250
20
Double - 250
21
Double - 250
INPUT VOLTAGE RANGE: 12-24V AC or DC
TEMPERATURE RATING: -40°C to +65°C (-40°F to 149°F)
TYPICAL POWER CONSUMPTION AT 25°C
Voltage Flash Mode
Steady Mode - High
12V DC
0.24 A Max
0.24 A
24V DC
0.12 A Max
0.12 A
12V AC
1.1 A rms Max
0.53 A rms
24V AC
0.22 A rms Max
0.22 A rms
NOTE: Average current draw in Flash Mode will vary by selected Flash mode. The above maximum amperage draw is
stated at Single 60 FPM.
PROGRAMMING PRIMARY & SECONDARY MODES
1. Remove power from unit.
2. Short the Yellow wires together.
3. Restore power to the unit and wait until the unit begins to flash. Once the unit begins to flash, remove the short. The unit will
alternately demonstrate the Secondary-Flash Mode and Primary-Steadyburn Mode that will be displayed during operation. For
approximately 4 seconds the Secondary-Flash Mode will be demonstrated, followed by the Primary-Steadyburn Mode.
4. To select the next mode of operation, momentarily short the yellow wires. The unit will cycle to the next mode in the list above.
5. There are seven Flash Modes and three Steadyburn Modes combinations to choose from.
6. When you reach the desired mode of operation, remove power from the unit. You MUST leave power disconnected for 20 seconds
BEFORE reapplying. When power is reapplied, the unit will operate as programmed above.
NOTE: If you do not leave power disconnected for 20 seconds before reapplying power, the light will default to Program Mode.