Fix the latch with the wood screws, with the bevel towards
the door frame.
Fit latch support post into back of the code side front
plate according to the hand of your door, A for a right
hand door, or B for a left hand door (see diagram).
If not using fixed length bolts, cut two of the socket head
bolts to the required length for your door. Approximate
overall length should be door thickness plus 25mm (1”)
to allow about 10mm (
3
/
8
”) of threaded bolt to enter
the outside plate.
Apply the front and back plates, with the neoprene
seals in position, against the door, over the protruding
ends of the spindle.
Fix the two plates together using the socket head bolts,
starting with the top fixing. Ensure that the two plates
are truly vertical and then tighten the bolts using the
‘T’ shaped Allen key. Do not use excessive force.
Before closing the door, enter the code and ensure
that the latchbolt will retract when the lever handle is
depressed. Now check the operation of the inside lever
handle. If there is any binding of the handles or latch
then loosen the bolts slightly and reposition the plates
slightly until the correct position is found, and then
re-tighten the bolts.
STEP 10
STEP 11
STEP 12
STEP 13
STEP 9
A