Important!:
Replace the brew  lter after every 7,500 coffees.
Wash all these parts with warm water
and a brush.
Wash the inside and top of the brew
cylinder with warm water and a brush.
Step 7: Cleaning the brewing system - VKI brewer equipped models (continued)
MONTHLY CLEANING PROCEDURE
Reassemble the  lter in the brewer by
aligning the tab towards the back of the
cylinder, then press down on both sides
of the  lter with medium force until the
lter snaps down into the cylinder and is
ush with top of the cylinder.
Reassemble the brew chamber on the
brewer by aligning the protruding guides
with the slots on the support bracket
and slide the chamber straight in fully
until the latch catches. Make sure that
the grounds scraper is between the
scraper drive arms during reassembly.
Dry all parts and set aside.
Pro Tip:
Save time by exchanging dirty parts with clean spares and
washing and drying the dirty parts later (in a dishwasher if
dishwasher-safe) then reusing them for the next cleaning.