Discrete I/O
operating
Limits
HS Output 0, 1, 2, 3 I
MAX
@ 24 VDC 50 mA
R
MAX
@ 12 VDC 150 Ω
@ 24 VDC 470 Ω
Input 0 (Trigger) V
IH
±15 — ±25 V
Input 1 V
IL
0 — ±5 V
I
TYP
@ 12 VDC 2.0 mA
@ 24 VDC 4.2 mA
Power Supply
Requirements
l PoE powered: Class 1 PoE supply, maximum 3.84 W, or
l External power supply (no PoE): +24 VDC +/- 10% (1 A maximum, 5 W average)
Supplied by LPS or NEC class 2 only
Power
Consumption
<3.84 W (PoE Class 1)
<5 W (average, externally powered at +24 V)
DataMan 260 Series Imager Specifications
Specification DataMan 260 Imager DataMan 262 Imager
Image Sensor 1/3 inch CMOS 1/3 inch CMOS
Image Sensor
Properties
4.51 mm x 2.88 mm (W x H), 6.0 μm
square pixels
4.8 mm x 3.6 mm (W x H), 3.75 μm square
pixels
Image Resolution
(pixels)
752 x 480 1280 x 960