17
OM.MC.20160506
TROUBLESHOOTING
UNCLOG THE DRY ICE CHUTE
Always wear proper personal protective equipment including eye protection to
guard against flying objects, ear protection to prevent hearing loss and gloves to
protect hands from exposure to cryogenic temperatures and sharp blade surfaces.
To unclog the dry ice chute:
1. Remove the dry ice
2. Set the feed rate control to maximum and move the applicator mode select
switch to the air + ice position (II).
3. Close the trough door and press the green power on/reset button . Hold
this button down until the green light turns on.
4. Open the chute access port.
5. Blow out the dry ice with the applicator nozzle until clear.
Dry ice will blow out. Protect eyes, face and skin from contact with dry ice particles.
Remember to use preventive methods to avoid clogging in extremely humid
environments:
• Before loading dry ice, clean excess moisture from the trough area.
PROBLEM CHECK THIS SOLUTION
Machine will
NOT blast
(cont’d)
STILL will
not blast
PROBLEM CHECK THIS SOLUTION
Machine will
NOT blast
(cont’d)
STILL will
not blast
If the problem is not resolved, please contact our Customer Support Hotline at:
+1-800-777-9101 (+1-513-576-8981)