5
P61318 P6680
P6916
A
B
1) Open/unscrew the air purge valves on the filter pump; air will be released as water fills the filter pump.
2) When water comes out of the air purge valves, close the air purge valves and wipe away any remaining water.
3) Test the GFCI plug.
4) Start the filter pump by pressing the switch button.
Operation
A. To test the GFCI, plug it into a grounding type receptacle.
B. Press the “RESET” button; the indicator should turn red.
NOTE: If the indicator light is not on, the test has failed.
C. Press the “TEST” button. The indicator should turn off.
NOTE: If the indicator light is not off, the test has failed.
D. Press the “RESET” button. If the indicator light turns red, the filter pump is ready for use.
WARNING: RISK OF ELECTRIC SHOCK: THE GFCI MUST BE TESTED BEFORE EACH USE.
WARNING: DO NOT USE THE PUMP IF THE ABOVE TEST FAILS.
Please contact your local Bestway Customer Service.
NOTE: Never operate the pump while the connection valves are closed.
NOTE: To prevent the risk of electrical shock, ensure your hands are completely dry when plugging-in the filter pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP - Make sure both the pool’s Inlet and Outlet valves are fully
covered by water before operating the filter pump.
GFCI Test
RESET
TEST
RESET
TEST
RESET
TEST
A B
C
D
303021233056_90445E_14x21cm_客专2000galAPP过滤泵说明书_20N-OEM-481