260614-CTG-C-0407
2 Unitary Products Group
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
* Wire size and overcurrent protection must comply with the National Electric Code.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
13-7/8
7/8
23-3/4
7/8
30-1/8
1-1/2” GAS
PIPE ENTRY
7/8” JUNCTION
BOX HOLE
T-STAT WIRING
7/8” K.O.
CONDENSATE
DRAIN 7/8” K.O.
OPTIONAL RETURN AIR
CUT-OUT (either side)
FOR USE WITH
EXTERNAL FILTER
FRAME
LEFT SIDE
RIGHT SIDE
26-3/4
1-1/2
1-1/4
C
24-3/8
20
5/8
5/8
B
24-17/16
2
D
BOTTOM IMAGE
RETURN END
TOP IMAGE
SUPPLY END
1-1/2” GAS
PIPE ENTRY
7/8” JUNCTION
BOX HOLE
T-STAT WIRING
7/8” K.O.
CONDENSATE
DRAIN 7/8” K.O.
A
40
FRONT
CABINET AND DUCT DIMENSIONS
Models
Nominal
CFM
Cabinet
Size
Cabinet Dimension
A (in.) B (in.) C (in.) D (in.)
FC9V040A12UP11 1200 A 14-1/2 13-1/2 11-1/2 6-1/4
FC9V060B12UP12 1200 B 17-1/2 16-1/4 14-1/2 8-1/2
FC9V080B12UP11 1200 B 17-1/2 16-1/4 14-1/2 8-1/2
FC9V080C16UP12 1600 C 21 19-3/4 18 8-7/8
FC9V100C20UP12 2000 C 21 19-3/4 18 8-7/8
FC9V120D20UP12 2000 D 24-1/2 23-1/4 21-1/2 10-5/8
ELECTRICAL AND PERFORMANCE DATA
Models
Input
High/Low
Output
High/Low
Nominal
Airflow*
Cabinet
Width
Total Unit AFUE
High Fire
Air Temp. Rise
Low Fire
Air Temp. Rise
MBH MBH CFM In. Amps % °F °F
FC9V040A12UP11 40/26 38/24 1200 14-1/2 9 94.0 35 - 65 35 - 65
FC9V060B12UP12 60/39 56/36 1200 17-1/2 9 95.0 40 - 70 20 - 50
FC9V080B12UP11 80/52 75/49 1200 17-1/2 9 92.5 45 - 75 45 - 75
FC9V080C16UP12 80/52 75/49 1600 21 12 95.0 45 - 75 20 - 50
FC9V100C20UP12 100/65 93/60 2000 21 14 95.0 45 - 75 20 - 50
FC9V120D20UP12 120/78 112/73 2000 24-1/2 14 95.0 40 - 70 20 - 50
Models
Input
High/Low
Max. Outlet
Air Temp.
Blower
Blower
Size
Max.
Over-
current
Protect
Min. Wire Size
(awg) @ 75 ft.
One Way
Operating
Wgt.
MBH °F HP Amps In. Lbs.
FC9V040A12UP11 40/26 165 1/2 7.7 11 x 8 20 14 121
FC9V060B12UP12 60/39 170 1/2 7.7 11 x 8 20 14 135
FC9V080B12UP11 80/52 175 1/2 7.7 11 x 8 20 14 142
FC9V080C16UP12 80/52 175 3/4 9.6 11 x 10 20 14 157
FC9V100C20UP12 100/65 175 1 12.8 11 x 11 20 12 164
FC9V120D20UP12 120/78 170 1 12.8 11 x 11 20 12 180