A. To test the GFCI plug, insert it into a grounding type receptacle.
B. Press the “RESET” button; the indicator turns red.
NOTE:
If the indicator light is not on, the test has failed.
C. Press the “TEST” button. The indicator turns off.
NOTE:
If the indicator light is not off, the test has failed.
D. Press the “RESET” button, the indicator light turns red, and the filter pump is ready for use.
WARNING:
RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH USE.
WARNING:
DO NOT USE THE PUMP IF THE ABOVE TEST FAILS.
Please contact your
local Coleman Aftersales Service.
NOTE:
To prevent the risk of electrical shock, ensure your hands are completely dry when
plugging-in the Filter Pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP - Make sure both the pool’s
Inlet and Outlet valves are fully covered by water before operating the Filter Pump.
MAINTENANCE
CAUTION:
YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY
MAINTENANCE OR STORAGE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
1) Unplug the Filter Pump.
2) Loosen the Hose Clamps on the pool’s Inlet and Outlet Hoses by unscrewing the fly nut counter-clockwise.
3) Remove Debris Screens from the inside of the pool.
4) Replace the Debris Screens with the Stopper Plugs in the pool’s Inlet and Outlet Valves.
5)
Unscrew the Filter Cap Retainer and remove the Filter Cap.
6)
Clean the Filter Cartridge with a garden hose, if filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
7)
Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
8)
Check that the Filter Cap Seal is in place.
9)
Replace the Filter Cap and screw the Filter Cap Retainer into position.
10) Replace the Stopper Plugs with the Debris Screens in the pool’s Inlet and Outlet Valves. Tighten the Hose Clamps. Water will now flow to the pump.
11) Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT:
For sanitary reasons we suggest replacing the Filter Cartridge with a new
one every two weeks.
PUMP STORAGE
1) Unplug the Filter Pump.
2)
Follow the instructions as previously outlined to stop water flowing to the Filter Pump and to remove the Filter Cartridge.
3) Discard the Filter Cartridge.
4) Detach all Hoses.
5) Dry all components thoroughly.
6) Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-40
º
C (39.2-104F)
PUMP WARRANTY
For information concerning pump warranty please visit our website at: www.colemanabovegroundpools.com
NOTE:
It is imperative to check that the hydraulic connectors are not closed.
GFCI Test
RESET
TEST
RESET
TEST
RESET
TEST
A B C D
6
S-S-004232

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Coleman FlowClear 90402E and is the answer not in the manual?

Coleman FlowClear 90402E Specifications

General IconGeneral
BrandColeman
ModelFlowClear 90402E
CategoryWater Pump
LanguageEnglish

Related product manuals