5005749-CTG-A-0216
Johnson Controls Unitary Products 7
— = Not applicable.
* Notates “Hot Heat Pump” performance. These ratings are not AHRI listed.
MP Modular Air Handlers use Coil Only Ratings.
3. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
TH4B4821S AVC48CX21 21.0 1,375 46.0 31.6 14.25 12.00 47.5 31.4 9.00 3.56 2.62 41.5 31.0
TH4B4821S AVC48DX21 24.5 1,400 46.5 31.6 14.75 12.25 47.5 31.2 9.00 3.60 2.66 42.0 33.4
TH4B4821S AVC60CX21 21.0 1,350 46.5 31.6 15.00 12.50 47.5 31.2 9.00 3.56 2.62 42.0 30.7
TH4B4821S ME14DN21 24.5 CF/CM48D 1,400 46.5 32.0 14.50 12.25 47.5 31.4 9.00 3.60 2.66 42.0 33.7
TH4B4821S ME14DN21 24.5 CF/CM60D 1,400 46.5 32.0 14.25 12.00 48.0 31.4 9.00 3.54 2.60 42.0 33.7
TH4B4821S ME16CN21 21.0 CF/CM48C 1,400 46.0 31.8 14.50 12.00 47.5 31.4 9.00 3.58 2.64 41.5 33.4
TH4B4821S ME16CN21 21.0 CF/CM60C 1,400 47.0 32.2 14.50 12.25 47.5 31.2 9.00 3.58 2.62 42.4 34.1
TH4B4821S ME20DN21 24.5 CF/CM48D 1,400 46.5 31.8 14.50 12.00 47.5 31.4 9.00 3.60 2.66 42.0 33.4
TH4B4821S ME20DN21 24.5 CF/CM60D 1,400 47.0 32.2 14.75 12.25 47.5 31.2 9.00 3.58 2.64 42.4 34.1
TH4B6021S AE60DX21 24.5 1640 55.5 38.5 14.25 12.00 57.0 37.8 9.00 3.88 2.82 51.9 41.0
TH4B6021S AVC60DX21 24.5 1550 55.5 38.5 14.25 12.00 57.0 37.8 9.00 3.88 2.82 51.9 41.0
TH4B6021S ME20DN21 24.5 CF/CM64D 1600 55.0 38.0 14.25 12.00 57.0 37.6 9.25 3.88 2.82 51.6 40.9
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
1. Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
2. Heating MBH based on AHRI standards of 70°F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
COP (Coefficient of Performance) equals Heating MBH output divided by (total KW input x 3.412).
SYSTEM CAPACITY - Single Piece and Modular Air Handlers
UNIT
MODEL
AIR HANDLER
COIL
MODEL
3
RATED
CFM
COOLING
1
HEATING
2
TVA COOLING
MODEL WIDTH
NET MBH
SEER EER
NET MBH
HSPF
COP NET MBH
TOTAL SENS. 47°F OD 17°F OD 47°F OD 17°F OD TOTAL SENS.