TheComcoWarranty
ComcowarrantsthattheAccuFlo®modelAF10‐Ewillbefreefromalldefectsinmaterialandworkmanship
undernormaluseforaperiodofoneyearfromthedateofpurchaseor2,000hoursofnormaloperation,
whichevercomesfirst.
ThewarrantyperiodbeginswhentheequipmentshipsfromtheComcofacilityandappliestotheoriginal
owneronly.Comco isnotliablefordamagesfromanycauseoruseofsuchequipmentbeyondthecostof
repairinganydefectiveparts.
Iftheequipmentfailstoperformsatisfactorilyduringthewarrantyperiod,Comcohastheoptiontodoany
oneofthefollowing:1)Sendreplacementpartstothecustomertobeinstalledbythecustomer;2)Repair
theunitatthecustomer’sfacility;or3)RequestthattheunitbereturnedtotheComcofactory.Any
replacementpartsshallbefurnishedbyComcowithoutcost,F.O.B.theComcofactoryinBurbank,California,
providedthatComcoisnotifiedofthedefectwithinthewarrantyperiod.Anydefectivepartsshallbe
returnedtoComcoforinspectionandanalysis.
Exclusions
Theabovewarrantydoesnotapplytodefectsorproblemsresultingfromimproperorinadequate
maintenancebythecustomer;unauthorizedmodificationormisuse;failuretofollowtheoperating
instructions;theuseofanysuppliesorparts,includingbutnotlimitedtonozzles,powders,andattachments,
notmanufacturedorsuppliedbyComco.
Thewarrantyalsodoesnotcoverproblemsresultingfromimproperorinadequatefacilities(contaminated
air;improperpower)oritemsthatshouldbeexpectedtowearinnormaloperation,suchasnozzles,
abrasives,tubingorfittings.
ThisisComco’sonlywarrantyandisinlieuofallotherwarrantiesofmerchantabilityandfitnessforany
particularpurpose.Norepresentationsorwarrantiesareauthorizedexceptashereinstated.
AlwaysoperatetheAccuFlo®blasterinanappropriate
workstationwithdustcollection.
Neverblasttowardsomeone’sfaceoreyes.Thisisa
pressuredevice.
TheLexanwindowonthetankcoverisabrasion
resistant.However,contactwithcertainchemicalscan
weakenthecoverandcauseittocrack.
Inspectthecoverdailyandreplaceimmediatelyif
cracksdevelop.
RefertoComcoTechnicalSupportforfulldetails.
13
TechSupport:1‐818‐841‐5500
WARNING
MAXIMUMBLASTSETTINGONYOURBLASTER
Neveroperateanymicro‐abrasiveblasterwith
theairpressureregulatorfullyopen.Checkyour
compressorsettingstodeterminetheairpressure
levelitusestotriggerthere‐pressurizecycle.The
blastpressuresettingonyourblastershould
alwaysbesetat10psibelowthispoint,whichis
thelowestsupplypressurecomingfromyour
compressor.Iftheinletpressuredropsbelowthe
blastpressuresetting,airandabrasivewillflow
backwardthroughyoursystemanddamage
criticalcomponents.