16
• Openthewatersupplytapandmakesurethisisnotdripping;
- if the connection is made to the drinking water mains, a
BA
type water mains disconnector (26) must
be used, in conformity with EN 12729 standard, and available from your dealer
(fig. 5).
With regard to
its use, refer to the relative instruction manual;
- in case of supply from a water tank, introduce the suction hose inside the tank and make sure the vertical
distance between the water level and the pump is no more than 1.5m (4.9ft).
operaTion g in fig. 5.
• Makesurethemasterswitch(1)ison“0”positionandinserttheplug.
operaTion C in fig. 4.
• Movethemasterswitch(1)toposition“1”.
• Pressthespraygunlever(19)andwaitforacontinuousjetofwatertocomeout;
- ETM 130: in case of supply from a water tank, load the pump by pressing the “Priming” button (27)
fig.5
; release this when a continuous jet of water starts to come out of the spray gun.
• Movethemasterswitch(1)to“0”positionandconnectthelancehose(10)tothespraygun(9),tightening
well.
operaTion B in fig. 4.
STANDARD OPERATION (HIGH PRESSURE)
• Makesurethenozzleholderhead(11)isnotinthedetergentdispensingposition(referto
“OPERATION
WITH DETERGENT”
paragraph).
• Startthehigh-pressurecleaneragainmovingthemasterswitch(1)toposition“1”.
• Pressthegunspraylever(19),makingsurethesprayofthenozzleisevenandthisisnotdripping.
• Ifnecessary,adjustthepressurebyturningtheknob(6).Turnclockwisetoincreasepressure,anticlockwise
to decrease it.
OPERATION WITH DETERGENT
The detergents recommended by the Manufacturer are over 90% biodegradable.
For instructions on how to use them, refer to the indications on the label of the detergent pack.
• Movethemasterswitch(1)to“0”position.
• Insertthedetergenthose(17)intheconnection(24)onthepumphead,looseningtheelasticclamp(25)
using pliers as shown in
fig. 3
.
• Introducetheotherendof thehose(17)includingthelter(16)intotheexternaltank,whichwill
already have been prepared with the detergent with the required dilution. In this case as well, follow the
suggestions relating to dosage shown on the label of the detergent pack.
• Operateonthenozzleholderhead(11)asshownin
fig. 2- posiTiona
.
• Startthehigh-pressurecleaneragain,movingthemasterswitch(1)toposition“1”andoperatethe
lever(19): suction and mixing occur automatically as the water ows through.
• Tostopthesupplyofdetergentandrestorehigh-pressureoperation,stopthehigh-pressurecleaner
moving the master switch (1) to “0” position and operate on the head (11) as shown in
fig. 2- posiTionB
.
STOPPING OPERATION
• Withoperatingpressuresabove20bar/290psi,thehigh-pressurecleanerautomaticallystopsbyreleasing
the spray gun lever (19), through the Total-Stop device. It starts operating again when pressing the spray
gun lever.
STOP
• Completelyclosethewatersupplytap(orremovethesuctionhosefromthewatertank).
• Emptythewaterfromthehigh-pressurecleaner,allowingthistooperateforafewsecondswiththespray
gun lever (19) pressed.
• Movethemasterswitch(1)to“0”position.
• Removetheplugfromthepowersocket.
• Eliminateanyresidualpressureinthehigh-pressurehose(14),bykeepingthespraygunlever(19)pressed
for a few seconds.
• Waitforthehigh-pressurecleanertocooldown.