4 INSTALLATION
4.1 assEMblIng thE accEssorIEs
a) Insert the handling bar (3) onto the body of the high pressure cleaner. Make sure you fully insert
the bar into the high-pressure cleaner’s body (the front surfaces must be aligned with one another).
Secure the bar with the 2 screws supplied (cross head screwdriver not supplied). Step A in Fig. 2
b) Unroll the high-pressure hose (23), connect the quick-t connector (24) to the water outlet
connector(8), screw down and secure. Step C in Fig. 3.
c) Screw the end of the high pressure hose (23) (the end without the quick t connector) onto the
thread of the spray gun (14) and secure it tightly using two 17 mm socket keys (not supplied).
StepD in Fig.3.
4.2 chEcks and connEctIon to thE MaIns WatEr supply
CAUTION
• The water supply must be able to guarantee the adequate delivery of water ow to the high pressure
cleaner; refer to the table of technical specications.
In case of doubt, contact a Skilled Technician.
• Do not supply the water cleaner with water at a temperature in excess of 50°C/122°F or below 5°C/41°F.
• The pressure of the water supply must not be in excess of 8 bar/116 psi.
• Do not operate the high pressure cleaner with a priming depth in excess of 0 m/0 ft.
• Do not operate the high pressure cleaner if it is not connected to a water supply.
• Do not supply the high pressure cleaner with salt water or water containing impurities. In this event,
run the high pressure cleaner for a few minutes with clean water.
WARNING
• Follow current regulations for connection to the mains water supply in the country where the water cleaner
is installed.
4.3 chEcks and connEctIon to thE MaIns ElEctrIcIty supply
WARNING
• A Skilled Technician must check that the electrical supply complies with the data indicated on the
identication label (7) on the high pressure cleaner. It is especially important that the supply voltage does
not dier more than ±5% from that indicated on the label.
• All connections to mains electricity must be carried out by a Qualied Eletrician according to IEC 364
regulations or the equivalent standard in the country where the high pressure cleaner is to be used. It is
especially important that the current outlet where the high pressure cleaner is connected is provided with
an earth conductor and a suitable fuse (according to the size indicated on the identication label and in the
table of technical specications), and must be protected by a magneto-thermal dierential circuit breaker,
whose sensitivity is not in excess of 30 mA.
• If the power supply cable is too short, an extension cord can be used provided it is not longer than 10m/32.8ft,
the section of the wires is at least 1,5mm² and the plug and the socket are waterproof. Contact a Qualied
Eletrician so that all these requirements are followed.
The use of unsuitable extension cords can be dangerous.
5 OPERATION
WARNING
• The high pressure cleaner must be used with care and attention. It is your responsibility to make sure that
any infrequent users have read these instructions and are acquainted with the operation of the water
cleaner; otherwise do not allow others to use the high pressure cleaner. Water cleaners must not be used