EasyManuals Logo

Comet static 1700 User Manual

Comet static 1700
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
19
STOPPING  TOTAL STOP
Release the lever (22) of the high pressure water gun and the cleaner will stop automatically.
The cleaner will start again regularly the next time the lever of the high pressure water
gun is pressed.
STOPPING
Completely close the water supply tap (or remove the suction pipe from the tank).
Run the high-pressure cleaner for a few seconds with the lever (22) of the gun pressed to
expel any excess water.
Place the master switch (1) into position “0”.
Remove the plug from the power socket.
Eliminate any residual pressure that has remained in the high-pressure pipe (34) by pressing
the lever (22) of the gun for a few seconds.
Wait for the high-pressure cleaner to cool.
STORAGE
Reel-up the high pressure hose (34) with care and without bending it.
Wind-up the power supply cable with care.
When using on the oor, put the high pressure water cleaner away carefully in a dry and
clean place.
Make sure not to damage the power supply cable and the high pressure hose.
ROUTINE MAINTENANCE
Carry out the operations described in paragraph “STOPPING, following the table below.
MAINTENANCE INTERVAL OPERATION
On every use Check the power cable, high-pressure pipe, connectors, gun and lance pipe.
If one or more parts are damaged, do not use the high-pressure water cleaner and contact a QUALIFIED
TECHNICIAN.
Weekly Cleaning of inlet water lter (18).
Unscrew the hose connector (25) or (27) and remove the lter (18).
Cleaning the lter under running water or compressed air is generally
sucient. In more dicult cases, use a scale-removing product or replace
it by contacting an authorised assistance centre to purchase it.
Ret the lter and tighten the hose connector.
Monthly Cleaning the nozzle.
It is usually sucient to clean the hole of the nozzle with the pin supplied
(31). If this operation fails to satisfactorily clean the nozzle, replace the
latter by ordering a spare part from an authorised service centre.
The nozzle is replaced using the key (32) (supplied).