EasyManua.ls Logo

Comet XTREME - User Manual

Comet XTREME
120 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EN •
Cold Water, Electric High Pressure Cleaners Instruction manual - Use and Maintenance
FR •
Nettoyeurs haute pression électriques à eau froide Notice technique - Utilisation et Entretien
ES •
Hidrolavadoras eléctricas de agua fría Manual de Instrucciones - Uso y Mantenimiento
DE •
Elektrische Kaltwasser-Hochdruckreiniger Bedienungs- und Wartungsanleitung
NL •
Elektrische koud water hogedrukreinigers Instructiehandleiding - Gebruik en Onderhoud
PL •
Elektryczne myjki wodne z zimną wodą Instrukcja - Obsługi i Konserwacji
PT •
Hidrolimpadoras eléctricas de água fria Manual de Instruções - Uso e Manutenção
SV •
Elektriska högtryckstvättar med kallvatten Bruks- och Underhållsanvisning
RU •
Электрические высоконапорные моющие Руководство - Эксплуатация И Обслуживание
аппараты с холодной водой
BG •
Водоструйни машини с подгряване на водата Инструкция за употреба – използване
и поддръжка
IT •
ATTENZIONE. Leggere le istruzioni prima di utilizzare
la macchina.
EN •
WARNING. Read the instructions before using the
machine
FR •
ATTENTION. Lire les instructions avant d’utiliser
l’appareil
ES •
ATENCIÓN. Leer atentamente las instrucciones antes
de utilizar la máquina.
DE •
ACHTUNG. Vor der Verwendung der Maschine die
Anweisungen lesen.
NL •
LET OP. Voor het gebruik van de machine de
aanwijzingen aandachtig doorlezen.
PL •
UWAGA. Przeczytać instrukcje przed użyciem
maszyny.
PT •
ATENÇÃO. Ler as instruções antes de utilizar a máquina.
SV •
OBSERVERA. Läs instruktionerna innan maskinen
används.
RU •
ВНИМАНИЕ. Перед использованием оборудования
необходимо прочитать данные инструкции.
IT
IdropulItrIcI ElEttrIchE ad acqua FrEdda
ManualE dIstruzIonE - uso E ManutEnzIonE
1001/1251/15011001/1251/15011001/1251/15011001/1251/1501
XTREMEXTREMEXTREMEXTREME
Italiano
English
Français
Español
Deutsch
Nederlands
Polski
Português
Svenska
Русский
Български
IT
FR
DE
PL
EN
NL
ES
PT
SV
RU
BG
Question and Answer IconNeed help?

Do you have a question about the Comet XTREME and is the answer not in the manual?

Overview

This document describes a range of electric cold water high-pressure cleaners, specifically the 1001, 1251, 1501, and XTREME models. It serves as an instruction manual for use and maintenance.

Function Description

The devices are electric cold water high-pressure cleaners designed for various cleaning tasks. They operate by pumping water at high pressure through a spray gun and lance, allowing for efficient removal of dirt, grime, rust, paint, and other encrustations from surfaces. The XTREME models offer additional features like an emergency stop button and a thermostatic valve for enhanced safety and performance.

Important Technical Specifications

The technical specifications vary across the models (1001, 1251, 1501, and XTREME series like 15/500 T, 21/350 T, etc.). Here's a summary of the common and varying parameters:

  • Electrical Connections:

    • Power Supply: 400 V – 3~50 Hz (common across all models).
    • Input Power: Ranges from 8.5 - 11.6 kW (1001, 1251, 1501) to 22.5 - 30.1 kW (XTREME 21/500 T).
    • Fuse: 32 A for 1001, 1251, 1501 models; 32 A or 63 A for XTREME models depending on power.
  • Hydraulic Circuit:

    • Max. Supply Water Temperature: 85 – 185 °F (1001, 1251, 1501); 60 – 140 °F (XTREME).
    • Min. Supply Water Temperature: 5 – 41 °F (common across all models).
    • Min. Supply Water Flow Rate: Ranges from 21 - 5.54 USgpm (1501 18/350 T) to 50 - 13.2 USgpm (1501 42/130 T, XTREME 42/200 T).
    • Max. Supply Water Pressure: 8 – 116 psi (common across all models).
    • Max. Priming Depth: 1.5 – 4.9 ft (models without Total Stop); 0 – 0 ft (models with Total Stop).
  • Performance:

    • Max. Flow Rate: Ranges from 16.5 - 4.4 USgpm (XTREME 15/500 T) to 42.5 - 11.2 USgpm (1501 42/130 T, XTREME 42/200 T).
    • Nominal Flow Rate: Ranges from 15 - 3.9 USgpm (XTREME 15/500 T) to 42.0 - 11.0 USgpm (1501 42/130 T).
    • Max. Pressure: Ranges from 130 - 1885 psi (1501 42/130 T) to 520 - 7540 psi (XTREME 15/500 T, 18/500 T, 21/500 T).
    • Nominal Pressure: Ranges from 120 - 1740 psi (1501 42/130 T) to 500 - 7250 psi (XTREME 15/500 T, 18/500 T, 21/500 T).
    • Min. Total Stop Triggering Flow Rate: 3 – 0.8 USgpm (common for models with Total Stop).
    • Max. Reaction Force on Spray Gun: Ranges from 64 N to 123 N.
    • Sound Pressure Level - Uncertainty: 86 – 0.7 dB(A) or 88 – 0.7 dB(A).
    • Sound Power Level: 93 dB(A) or 94 dB(A).
    • Operator Hand-Arm Vibration - Uncertainty: 2.4 – 0.24 m/s².
  • Pump Oil: ENI MULTITECH THT (for 1001, 1251, 1501 models) or 15W/40, MULTITECH (for XTREME models). Specific corresponding oils are listed (e.g., Mobil Mobilfluid 424, Total Rubia TIR 7400 15W-40).

  • Weight and Dimensions:

    • Dimensions (L x W x H): 900 x 750 x 950 mm (35.4 x 29.5 x 37.4 in) for 1001, 1251, 1501 models; 1000 x 750 x 950 mm (39.4 x 29.5 x 37.4 in) for XTREME models.
    • Weight: 160 – 353 kg (1001, 1251, 1501 models); 175 – 386 kg, 185 – 408 kg, or 190 – 419 kg (XTREME models).

Usage Features

  1. Safety Devices:

    • Ampere Cut-out Protection: Automatically (1001, 1251, 1501) or manually (XTREME) resettable. Stops the machine in case of excessive power absorption.
    • Pressure Unloader/Regulation Valve: Allows adjustment of working pressure and prevents dangerous overpressure.
    • Spray Gun Lever Lock Device: Safety stop (23) to lock the spray gun lever (22) in the closed position, preventing accidental operation.
    • Emergency Push Button (XTREME): Immediately stops the machine in hazardous situations. It has a mechanical retention and must be pulled upwards to reset.
    • Relief Valve (XTREME): Discharges excess pressure if the pressure regulating system malfunctions.
  2. Preliminary Activities:

    • Assembly: Connect the high-pressure hose (35) to the spray gun (24) and the quick-fit coupling (36) to the water outlet fitting (16). Insert the gasket (26) into the water inlet fitting (17) and screw on the hose-end fitting (25).
    • Water Supply: Fix a supply hose (19 mm/0.75 in ID for 1001/1251/1501, 30 mm for XTREME) to the water inlet hose-end fitting (25). Open the water supply tap (use a back-flow preventer if connected to drinking water mains) or place a suction hose in a tank.
    • Starting Procedure:
      • 1001/1251/1501 (without Total Stop): Move master switch (1) to "1".
      • 1001/1251/1501 (with Total Stop): Move master switch (1) to "1" and press/hold START button (21) until water comes out of the spray gun. The Total Stop device controls micro-leaks.
      • XTREME: Move master switch (1) to "1" (mains voltage LED (43) turns on). If emergency button (40) is pressed, pull it up to reset. Press START button (21).
    • Priming: Press spray gun lever (22) and wait for a continuous jet of water, indicating correct pump priming.
    • Connecting Lance: Connect the lance tube (33) to the spray gun (55) using the quick coupling (1001/1251/1501) or tighten the lance tube (29) to the spray gun (24) (1501 18/350, XTREME).
  3. Standard Operation (High Pressure):

    • Ensure the nozzle holder head (30) or device (32) is not in the detergent dispensing/low pressure position.
    • Open water supply.
    • Start the machine as per the starting procedure.
    • Press the spray gun lever (22) and check for a uniform, drip-free spray.
    • Adjust pressure using the pressure adjustment knob (8) (clockwise to increase, anticlockwise to decrease). Pressure value is shown on indicator (13).
    • To reduce pressure, use device (32) as shown in Fig. 3-a; to restore high pressure, use Fig. 3-b.
  4. Stopping Operation:

    • Temporary Interruption: If interrupting the jet without stopping the machine, engage the safety stop (23) on the spray gun.
      • 1001/1251/1501: Releasing the spray gun lever (22) puts the machine in by-pass mode, stopping automatically after ~15 seconds. Pressing the lever again resumes operation.
      • XTREME: Releasing the spray gun lever (22) stops the jet and puts the machine in by-pass. Pressing the lever again resumes operation.
    • Caution (XTREME): Do not leave in by-pass for more than 3 minutes; the thermostatic valve (48) will drain fluid to protect pump gaskets.
  5. Stopping the Machine:

    • Turn pressure regulation knob (8) anticlockwise to minimum pressure.
    • Close water supply or remove suction hose.
    • Drain water by operating the spray gun lever (22) for a few seconds.
    • Press STOP button (42) (XTREME).
    • Move master switch (1) to "0".
    • Remove power plug.
    • Discharge any residual pressure from the high-pressure hose by pressing the spray gun lever (22) for a few seconds.
    • Allow the machine to cool down.
  6. Decommissioning (Storage):

    • Disconnect spray gun (24) from high-pressure hose (35) and store it on supports (3).
    • Disconnect high-pressure hose from water outlet fitting (16), wind it carefully, avoiding bends.
    • Wind power cable (6) carefully, avoiding bends.
    • Store the high-pressure cleaner in a dry, clean place, ensuring no damage to hoses or cables.
    • Engage wheel brake (20) to prevent uncontrolled movement.
    • Note: After prolonged non-use, minor water dripping under the pump may occur, usually disappearing after a few hours. If it persists, contact a Specialized Technician.

Maintenance Features

Routine Maintenance:

  • Every Time Used:
    • Check power cable, high-pressure hose, fittings, spray gun, and lance hose for damage. If damaged, do not use and contact a Specialized Technician.
    • Check pump oil level with the motor off and machine cooled. Use indicator (50) or dipstick (14). Refer to "Specifications and Technical Data" for oil types if topping up is needed.
  • Weekly:
    • Clean water inlet filter (18). It's self-cleaning. Ensure the pressure washer is connected to water supply and tap is open. Turn knob (53) to allow water and dirt to flow out of opening (65). When fluid is clean, turn knob (53) in the opposite direction.
  • Monthly:
    • Clean water inlet filter (18) as above.
    • Clean the nozzle. Use cleaning pin (31) through the nozzle hole. If results are poor, replace the nozzle (available from authorized service centers). Nozzle can be replaced with a 14 mm box spanner.
    • Check soundness of water inlet and outlet circuits.
    • Check clamping of the pump to the engine and the engine to the frame. If insecure, do not use and contact a Specialized Technician.
  • Caution: During operation, the high-pressure cleaner should not be too noisy or show obvious water/oil drips. If so, have it checked by a Specialized Technician.

Special Maintenance:

Special maintenance must only be performed by a Specialized Technician.

  • Every 200 Hours:
    • Check the pump's hydraulic circuit.
    • Check pump clamping.
  • Every 500 Hours:
    • Change pump oil.
    • Check pump suction/delivery valves.
    • Check tightness of pump screws.
    • Check the pump regulation valve.
    • Check the safety devices.
  • Caution: Data in the table are approximate. More frequent maintenance may be needed for particularly heavy use.

Optional Accessories:

The standard fitting can be supplemented with various optional accessories:

  • Sandblasting lance: for smoothing surfaces, removing rust, paint, encrustations.
  • Drain cleaning kit: for unclogging pipes and ducts.
  • Different types of lances and nozzles.
  • Rotating brush: for cleaning fragile surfaces.
  • Rotating nozzle: for removing stubborn dirt.
  • Foam lance: for efficient detergent distribution.
  • Hose reel: for increased working range and practical storage.