US customer support 1-888-622-2377 | www.commandaccess.com | CA customer support 1-855-823-3002
1
A.
Kit Includes
Tools Required
MLRK1
INSERT Instructions
The Command Access MLRK1 is a eld-installable motorized latch-retraction kit for:
SPECIFICATIONS
Input Voltage: 24VDC +/- 10%
Wire gauge: Minimum 18 gauge
Direct wire run - no relays or access control units
in-between power supply & module
Recommended Power Supplies:
All Command Access exit devices & eld installable kits have been thoroughly cycle tested with Command
Access power supplies at our factory. If you plan on using a non-Command power supply it must be a
ltered & regulated linear power supply.
A. 60241 – MLRK1 motor
B. 60264 – mm4 module
C. 50453 – magnet bracket
D. 40040 – phillips Screws (x2)
• cordless drill
• 1/16” Drill bit
• minor cutting tools and file
• #0 phillips screwdriver
• #2 phillips screwdriver
E.
D.C.
B.
Average Latch Retraction Current: 2 Amp
Average Holding Current: 250 mA
High Torque Mode
Average Latch Retraction Current: 1.3 Amp
Average Holding Current: 215 mA
Standard Torque Mode
• MLRK1-JAC 12 - Jackson 1285, 1286 and 1295 series devices
• MLRK1-KAW17 - Kawneer 1686 and 1786 series devices
• MLRK1-AHT - AHT 8 and 9 series devices
F.
G.
H.
E. 40059 – cable mounting pad
F. 40060 – cable tie (x2)
G. 50636 – Cable guides (x3)
H. 50436 – 8’ Power cable

Other manuals for Command access MLRK1 Series

Questions and Answers:

Command access MLRK1 Series Specifications

General IconGeneral
TechnologyMicrowave Radar
Detection AreaAdjustable
Voltage12-24 VDC
Relay Output1x NO/NC, 5A 250V AC
Housing MaterialABS Plastic
Current Consumption<100mA
Operating Temperature-20°C to +55°C
Humidity0-95% non-condensing
Dimensions120mm