Page #15 background imageLoading...
Page #15 background image
14
[Reference]
Ȅ How to set up the CCU-310EV if the guard room is not installed.
(Household / Floor mode)
ȄIf there is a guard stationCDS-4GS installed,WXUQRIIWKHguad station and set the
household input mode on the lobby phone. (Household / Floor mode)
z Proceed after setting the household input mode on the lobby phone.
Household input mode on the lobby phone.
"Program" button Î Management password Î "Bell button" Î "Program" button Î
"15" Î "Bell button" : Lobby phone enters household input mode.
£ Press "ID SET" button on the CCU-310EV to call.
¤ ID of CCU-310 is displayed on the lobby phone.
¥ Input the ID No. set by DIP S/W.
¦ Input serial number as "0".
§ When the input is complete, exit the household input mode on the lobby phone.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Commax CCU-310EV and is the answer not in the manual?

Commax CCU-310EV Specifications

General IconGeneral
Model Name Spec.CCU-310EV
Wiring481 DATA : 2 lines (Polarity) / E/V connection : 2 lines (Non-polarity) RS-485 : 3 lines (Polarity)
Distance1Km (Pie 0.65 wire basis)
VoltageDC 12V / 1A
Power ConsumptionStandby : 55mA / Operation : 70mA
Operating Temp.0~+40℃