16
Θ Set ID of CCU-310EV by DIP switch.
z Set ID of CCU-310EV by DIP switch’s “S/W5~S/W8”
Ι Press call button to call guard station.
Κ Shown ID of CCU-310EV on guard station. (Shown like “9500-XXXX”)
(ex) DIP switch “8” is ON, “9500-0001” is shown.
Λ Set the same building number as you set building number on the guard station.
Room number is set to be same with CCU-310EV’s ID number ( ID set by DIP switch)
Μ The ID of CCU-310EV changes.
z CCU-310EV 1 unit (one ID) can cover 10 units of lobby phones (10 buttons of EL call).
Ex. 1) Connect CCU-310EV "ID 1" to the product serial number "XXXX-9901 ~ XXXX-9910".
¾ If you connect a lobby phone to CCU-310EV "ID 1" product in 101,
you can connect up to ten Lobby phones sequentially from 0101-9901 to 0101-9910.
Ex. 2) Connect CCU-310EV "ID 2"
to the product serial number "XXXX-9911 ~ XXXX-9920".
¾ If you connect a lobby phone to CCU-310EV "ID 2" in building 102,
you can connect up to ten Lobby phones sequentially from 0102-9911 to 0102-9920.