7
Η Set DIP switch to be household input mode.
*( S/W1 Î OFF , S/W2 Î OFF)
Θ Set ID of CCU-310EV using DIP switch (S/W3 ~ S/W8).
(Refer to 5-1-1. “ID setting method by DIP switch”)
Ι Press “ID SET” button to call guard station.
Κ ID of CCU-310EV shown on guade station. (shown like "9501-XXXX")
ex) If S/W8 is ON , shown like “9501-0001”.
(Remark)
Ȅ Meaning of “9501 – 0001”
“9501” : Serial number of CCU-310EV device (household input mode / household floor mode)
“0001” : ID of CCU-310EV just set (by DIP switch)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Commax CCU-310EV and is the answer not in the manual?

Commax CCU-310EV Specifications

General IconGeneral
Model Name Spec.CCU-310EV
Wiring481 DATA : 2 lines (Polarity) / E/V connection : 2 lines (Non-polarity) RS-485 : 3 lines (Polarity)
Distance1Km (Pie 0.65 wire basis)
VoltageDC 12V / 1A
Power ConsumptionStandby : 55mA / Operation : 70mA
Operating Temp.0~+40℃