15. Setting the Number of Call Ring Repetitions
P - Management Password - E - 25 - E - 0 - E : Continuous call ring enabled.
P - Management Password - E - 25 - E - 1 - E : 1 time call ring enabled.
This function sets number of call ring repetition when a call is made to any households or
security office.
Press Program Button "P".
Press Management Password.
Press Call Button "E".
Press "25" (Program Number).
Press Call Button "E".
Select the mode
(0 : Continuous call ring)
(1 : 1 time call ring)
Press Call Button "E".