Ambient Temperature Sensor Calibration
Dispenser Calibration
Compac Industries Ltd.
Page 70
www.compacngv.com
Ambient Temperature Sensor Calibration
Calibrating the Ambient Temperature Sensor involves:
1. Comparing the dispensers stated temperature to the actual
temperature.
2. Adjusting the ambient temperature reading if it is found to be incorrect.
Test the sensor accuracy
Using a calibrated temperature meter, determine the temperature of the
body of the dispenser Ambient temperature sensor.
Access the current dispenser ambient temperature reading (see page 29).
Adjust dispenser reading
Adjust the dispenser’s ambient temperature reading to match that of the
calibrated temperature meter (see page 29).