8.5.3 Setting time/date (timer)
The DELCOS
Pro
accumulator can bridge a loss of
power lasting between around two to three weeks. If
power is lost for longer periods, the timer's time and
date are lost and have to be entered anew.
Press the
+
keys at the same time. Use
to go
to the [ TIMER CONTROL ] sub-menu and press the
key. The date and time are displayed there in the
following format:
TU 30.10.07 12:10:34
If you press the key, the left-hand value (day of the
week) starts to flash. You can now use the
or
keys to set this. Then confirm the value by pressing the
key.
All values can now be set in succession using this
procedure. When the last value (seconds) has been set,
the timer is fully set and you can exit the menu by twice
pressing the
+
keys at the same time.
8.6 Starting the unit
Danger
If the unit is ready, i.e. the green LED is flashing,
the compressor may automatically start at any time.
Use the main switch to switch the unit on.
If warning or fault messages appear in the third row of
the display, these first have to be rectified and
confirmed using the key.
Then start the unit by pressing the
I
key on the
DELCOS
Pro
.
8.7 Switching off the unit
The unit is switched off by pressing the
key on the
DELCOS
Pro
. However the unit will only stop after a 30-
second soft-stop.
The soft-stop is preset to protect the compressor.
Note
The unit may only be shut down using the emergency
off button in real emergencies. When shutting down
normally, please use the
key.
8.8 Emergency off button
The emergency off button is located above the
DELCOS
Pro
. It is used to immediately shut down the
unit. Only use the emergency off button to shut down
the unit in emergencies. When shutting down normally,
always use the
key.
8.9 Acknowledging warning /
fault messages
Warning and fault messages are shown in the third row
of the display. The red light signal flashes at the same
time.
You will find a table containing messages and
suggested ways of remedying problems in the separate
DELCOS
Pro
operating instructions.
8.9.1 Warning messages
When there are warnings, the red light signal flashes
slowly. The unit does not automatically shut down when
there are warnings. However ignored warnings may
cause faults.
Rectify what is causing the warning and press the
key to hide the warning.
8.9.2 Fault messages
Fault messages result in the unit automatically shutting
down or do not permit the unit to be started.
Once you have rectified the problem, you still have to
confirm by pressing the key.

Table of Contents

Other manuals for CompAir L22

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CompAir L22 and is the answer not in the manual?

CompAir L22 Specifications

General IconGeneral
ModelL22
CategoryAir Compressor
Motor Power22 kW
Motor Power (hp)30 hp
Noise Level67 dB(A)
Weight520 kg

Related product manuals