Ambient temperature too high
Ventilate compressor room
Check electric motor and thermistor
Cross section of the electric supply
lines too small
Measure power requirement,
if necessary, replace lines
Power requirement too high
Oil fine separator clogged,
replace, if necessary
Top up oil in the pressure reservoir
Oil injection pressure too low
Replace oil filter cartridge,
clean oil system
Excessive oil temperature
Check oil cooler and fan/
Check oil thermostat
Intake regulator does not close correctly
Excessive idling
pressure
Oil in the compressed air
Oil fine separator defective
Replace oil fine separator cartridge
Minimum pressure valve defective
Check minimum pressure valve
Intake regulator setback function
defective
Intake regulator does not close correctly
Frequent emergency shutdown
The emergency shutdown may only be
activated in the case of safety-relevant
functional problems
Oil fine separator clogged and final
compression pressure sensor defective
Replace oil fine separator cartridge and
change final compression pressure
sensor
Intake regulator closes too slowly
Check intake regulator and solenoid
valve
Mains pressure sensor defective
Replace mains pressure sensor
Danger
Never operate the screw compressor with defective safety valve!