NOTE: If the output is very slow, it could mean that the coffee is being ground too
ne.Iftheoutputisveryfast,itcouldmeanthatthecoffeeisbeinggroundtoocoarse.
A perfect espresso grind is found when the grind point gives an infusion of 25 ml of
coffee in 25 seconds using 7 grams of ground coffee.
9. OPERATION
9.1.Generalswitch
The general switch ( ) has 3 positions of use, I–0–II for E6 ESSENTIAL ON DEMAND
and E8 ESSENTIAL ON DEMAND (Fig. 7.1.) and AUTOMATIC-OFF-MANUAL for E10
CONIC ESSENTIAL ON DEMAND and E10 MASTER CONIC ESSENTIAL ON DEMAND
(Fig. 7.2.).
E6 OD,
E8 OD
E10 CONIC OD,
E10 MASTER
CONIC OD
Electrical functions
I AUTOMATIC
Off
0 OFF
Manual mode. Security sistem that allows
using the grinder in case of the supply plate or
keypad failure.
II MANUAL
9.2.Utilization
Through the program menu (section 10.3.), it is possible to select three distinct
functional modes: AUTOMATIC MODE, PRESLECT MODE and MANUAL MODE.