4.4 Calibration of the thermometer of the thermostat
You can calibrate the thermometer of the appliance (to correct
measured temperature). To this end all you have to do is change
the position of the orange-colored potentiometer by a Phillips
screwdriver. When you adjust the potentiometer clockwise then the
displayed temperature will be lower than that measured initially, and
when you adjust it anticlockwise the displayed temperature will be
higher than that. The displayed temperature can be adjusted within
a range of approx. ±4 °C.
Correction of the displayed temperature takes place a few seconds
after the adjustment.
ATTENTION! If the modication of the basic settings was done
after inserting the batteries and the modications did not take eect,
please press the RESETbutton located on the main panel of the
thermostat.