Installa tion l 3-15
3
Installa tion
Testing the Installation
You have completed the installation. Now it’s time to make sure everything works.
1 Make sure there is no material in the hopper. If you
have mounted a loader or vacuum receiver on the hop-
per, disconnect the material inlet hose at the source or
turn off the loader.
2 Turn on the main power to the dryer. Make sure the
dryer’s disconnect dial is in the ON position. This pow-
ers up the control and the display lights will illuminate.
3 Set the drying temperatures. Press temperature select
with the select category button, and then press the set-
point adjust (+) or (-) buttons or enter a low setpoint temperature
(150ºF {66ºC}) on the numeric keypad and press enter.
4 Press the START button.
If everything is installed correctly:
The green light on the start button will illuminate.
The process and regeneration blowers and LEDS will turn on.
The process and regeneration heaters and LEDS will turn on.
Auto Start
Dewpoint Control
Set-Back Temp.
Process Blower
Process Heater
Regen. Blower
Regen. Heater