Table of Contents

Questions and Answers

Summary

Electrical Checks and Adjustments

Downloading Scanner Firmware

Steps for downloading, installing, and managing scanner firmware updates.

Switch Mode Power Supply (SMPS) Check and Adjustment

Procedures for checking SMPS voltages, fuses, and adjustments.

Lamp and Motor Driver Board (LME) Check and Adjustment

Procedures for LME board checks, lamp driver adjustments, and signal LEDs.

Camera Board (CBE) Check and Adjustment (Non Tx and XL Models)

Procedures for checking and adjusting the CBE camera board.

Camera Board (CBF) Check and Adjustment (Tx and XL Models)

Procedures for checking and adjusting the CBF camera board.

Controller Board (SUC) Check

Procedures for checking the SUC controller board, including voltages and markings.

Interface Module (IMB) Check (Non Tx and XL Models)

Procedures for checking the IMB interface module, including voltages and markings.

Interface Module (IMD) Check (Tx and XL Models)

Procedures for checking the IMD interface module, including voltages and markings.

Operator Panel (SKD) Check

Procedures for checking the SKD operator panel, including voltages and switch settings.

Smart Card Reader (SCR) Check

Procedures for checking the SCR smart card reader, including voltages and DIP switch settings.

ATAC Motor Driver Board (MDA) Check

Procedures for checking the MDA ATAC motor driver board and its voltages.

Original Guide Sensors (ATAC) Check and Adjustment

Procedures for checking and adjusting ATAC original guide sensors for proper operation.

Adjustment of Original Sensors

Procedures for adjusting the original sensor switch points for accurate scanning.

CCD Cameras

CCD-Camera Check and Adjustment

Detailed procedures for checking and adjusting CCD cameras, including light profiles and focus.

Vertical Alignment and Horizontal Stitching

Vertical Alignment and Horizontal Stitching Procedure

Step-by-step guide for performing automatic vertical alignment and stitching.

Troubleshooting

Error Codes

Comprehensive list and interpretation of scanner error codes and messages.

Troubleshooting Hints

Practical tips and common solutions for troubleshooting various scanner issues.

Disassembly and Assembly

Replacement of Parts

SCANtest 6 Diagnostic Software

Contex CHAMELEON 36 Specifications

General IconGeneral
Optical resolution600 dpi
InterfaceUSB 2.0
Resolution600 dpi
Power SupplyUSB powered
Max scan width36 inches
Scanning TechnologyContact Image Sensor (CIS)