3.17 Check of Media Thickness Detector (not applicable to MAGNUM XL 54)
The two Media Thickness Detectors are located under the End Covers and are activated by
the left and right Media Thickness Adjustment Sliders when the Original Guide Plate is full
down in the Normal position (original thickness less than 2 mm).
3.17.1 Functional Test
SCANtest 6: Test 4, Original Sensor and Media Thickness Detector
While Test 4 runs, slide the Media Thickness Adjustment Sliders, one at the time, out and in
to turn the Wait LED on the Operator Panel ON/OFF.