15. TECHNICAL FEATURES
A. WATER SUPPLY
Minimum inlet pressure 24 Psi/ 1,5 bar
Water connection pin 3/8"
The water supply pipes must resist to 145 Psi/ 10 bar
Waterhardness for entrance water <10°thf (or 6°dh)
B. DRAIN
Without pressure
Drain with ribbed joining piece
The drain pipe must be lower than the machine to ensure that water cannot return to the
machine
C. POWER
Standard Machine: 200/240V - 50/60Hz for CC102i and CC103i
Special Machine: 230/400V - 50/60Hz for CC103i Tri
D. FEATURES
TYPE
MACHINE
HEATING
POWER
(W)
INSTALLED
POWER
(W)
ELECTRICAL
CONSUMPTION
With 230V (A)
CC102 D 3500 3800 17A
CC103 D 4700 5000 22A
CC103 D Tri 6000 6300 10A / phase
BOILER CAPACITY ( LITERS)
2G 3G
TOTAL 11 18
VOLUME OF HOT WATER 8 13
VOLUME OF STEAM 3 5
WEIGHT
empty
(Kg)
WEIGHT
in operation (Kg)
CC102