INTENDED USE: The
CONTOUR
®
TS
system (meter, test
strips, controls) is intended for self-testing by people with
diabetes and by health care professionals to monitor glucose
concentrations in fresh capillary whole blood drawn from the
fingertip. In clinical settings, the
CONTOUR TS
system may also
be used with fresh venous and arterial whole blood. The test
provides a quantitative measurement of glucose in blood from
0.6 mmol/L to 33.3 mmol/L.
The
CONTOUR TS
blood glucose monitoring system is not
intended for diagnosis of or screening for diabetes mellitus, and
is not for use in neonatal care.
Information For Safety
Read your CONTOUR TS user guide, the lancing device
insert and all instructional materials provided in your meter kit
before testing. Please follow all instructions for use and care
exactly as described to help avoid inaccurate results.
Wash and dry your hands well before testing.
Used test strips and lancets are possible biohazards and must be
disposed of as medical waste or as advised by your health care
professional.
The lancing device provided with your kit is intended for self
testing by a single patient. It must not be used by more than one
person due to the risk of infection.
Warning: Potential Biohazard
Health care professionals or persons using this system
on multiple patients should follow the infection control
procedure approved by their facility. All products or
objects which come in contact with human blood,
even after cleaning, should be handled as if capable
of transmitting infectious diseases. The user should
follow the recommendations for prevention of blood-
borne transmissible diseases in health care settings as
recommended for potentially infectious human specimens.
1
For complete cleaning instructions, see page 13.
5718657_CntrTS_Karajishi_UG_EN_FpBp_v1.indd IFCii 4/3/17 9:17 AM
Getting Started
Testing
Technical,
Service & Care
Your Meter Overview 2
Your Meter Features 4
Information For Safety 5
Error Codes and Symbols 24
Changing the Battery 28
Caring for Your Meter 29
Symptoms of High or Low Blood Glucose 30
System Specifi cations 31
Service Information 37
Warranty 38
Supplies 40
Setting the Time, Date and Sound 18
Transferring Results to a Computer 21
Viewing Stored Results 22
Table of Contents
Getting Ready to Test 7
Getting the Blood Drop 9
Testing Your Blood 10
Cleaning Your Meter 13
Control Solution Testing 14
Setup and Use
5718657_CntrTS_Karajishi_UG_EN_FpBp_v0.indd 1 3/24/17 4:13 AM
Getting Started
Testing
Technical,
Service & Care
Your Meter Overview 2
Your Meter Features 4
Information For Safety 5
Error Codes and Symbols 24
Changing the Battery 28
Caring for Your Meter 29
Symptoms of High or Low Blood Glucose 30
System Specifi cations 31
Service Information 37
Warranty 38
Supplies 40
Setting the Time, Date and Sound 18
Transferring Results to a Computer 21
Viewing Stored Results 22
Table of Contents
Getting Ready to Test 7
Getting the Blood Drop 9
Testing Your Blood 10
Cleaning Your Meter 13
Control Solution Testing 14
Setup and Use
5718657_CntrTS_Karajishi_UG_EN_FpBp_v0.indd 1 3/24/17 4:13 AM
INTENDED USE: The
CONTOUR
®
TS
system (meter, test
strips, controls) is intended for self-testing by people with
diabetes and by health care professionals to monitor glucose
concentrations in fresh capillary whole blood drawn from the
fingertip. In clinical settings, the
CONTOUR TS
system may also
be used with fresh venous and arterial whole blood. The test
provides a quantitative measurement of glucose in blood from
0.6 mmol/L to 33.3 mmol/L.
The
CONTOUR TS
blood glucose monitoring system is not
intended for diagnosis of or screening for diabetes mellitus, and
is not for use in neonatal care.
Information For Safety
Read your CONTOUR TS user guide, the lancing device
insert and all instructional materials provided in your meter kit
before testing. Please follow all instructions for use and care
exactly as described to help avoid inaccurate results.
Wash and dry your hands well before testing.
Used test strips and lancets are possible biohazards and must be
disposed of as medical waste or as advised by your health care
professional.
The lancing device provided with your kit is intended for self
testing by a single patient. It must not be used by more than one
person due to the risk of infection.
Warning: Potential Biohazard
Health care professionals or persons using this system
on multiple patients should follow the infection control
procedure approved by their facility. All products or
objects which come in contact with human blood,
even after cleaning, should be handled as if capable
of transmitting infectious diseases. The user should
follow the recommendations for prevention of blood-
borne transmissible diseases in health care settings as
recommended for potentially infectious human specimens.
1
For complete cleaning instructions, see page 13.
5718657_CntrTS_Karajishi_UG_EN_FpBp_v1.indd IFCii 4/3/17 9:17 AM
85718657_CntrTS_Karajishi_UG_EN_FpBp_v4_placed.pdf:2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Contour TS and is the answer not in the manual?

Contour TS Specifications

General IconGeneral
Sample Size0.6 μL
Test Time5 seconds
CodingNo coding required
Memory250 test results
Battery LifeApproximately 1000 tests
Measuring Range0.6 to 33.3 mmol/L
Battery1 CR2032 battery
Operating Temperature5°C - 45°C (41°F - 113°F)
Weight56.7 g (2 oz)