54 Unidrive M300/HS30 Quick Start Guide
Issue Number: 7
Reverse Select, which is controlled by the drive sequencer, is used to invert Reference Selected
(Pr 81) or the Jog Reference (Pr 15).
Jog Select, which is controlled by the drive sequencer, is used to select the Jog Reference (Pr 15).
This parameter displays the level of the analog signal present at analog input 1 (terminal 2).
This parameter displays the level of the analog signal present at analog input 2 (terminal 5).
92 Reverse Select
RO Bit ND NC PT
OL
Ú
Off (0) or On (1)
Ö
RFC-A
93 Jog Select
RO Bit ND NC PT
OL
Ú
Off (0) or On (1)
Ö
RFC-A
94 Analog Input 1
RO Num ND NC PT FI
OL
Ú
±100.00 %
Ö
RFC-A
95 Analog Input 2
RO Num ND NC PT FI
OL
Ú
±100.00 %
Ö
RFC-A