WebRelay-10 Plus™ Users Manual
Xytronix Research & Design, Inc. Page 20
Step 5: Select the radio button labeled “Use the following IP address” and type in the IP address
192.168.1.50. Type in a subnet mask of 255.255.255.0. No need to change the default gateway
eld. Click OK to accept the new settings.
Note: If “Use the following IP address” is already selected, the values need to be recorded, then reentered once
the IP address of the WebRelay-10 Plus™ is successfully changed.
2.3.3 Open Conguration Web Page
Once the network is set up, open the setup page as described in section 2.4. If the setup pages are not
accessible, verify that the WebRelay-10 Plus™ is powered on and that the LINK light is illuminated. Check all
network connections and settings. Another way to check communications is to ping the WebRelay-10 Plus™
(from the command prompt by typing ping {WebRelay-10 Plus™ Plus IP address} ).