EasyManua.ls Logo

ControlByWeb WEBRelay-10+ - Appendix F: Specifications; Power Requirements; Relay Contacts Specifications; Digital Inputs

Default Icon
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WebRelay-10 Plus™ Users Manual
Xytronix Research & Design, Inc. Page 32
Power Requirements:
- Voltage: 9-28VDC
- Max Current: 477mA - 1391mA
Relay Contacts:
- Number of Relays: 10
- N.O.
- 40A @ 240VAC resistive
- 30A @ 277VAC General Purpose
- 2hp @ 250VAC
- N.C.
- 30A @ 240VAC, 30VDC resistive
- 20A @ 277VAC General Purpose
- 1-1/2 hp @ 250VAC
- Contact Type: SPDT (Form 1C)
- Load Type: General Purpose
- Contact Resistance: < 30 milliohms initial
- Contact Material: AgSnO2
- Electrical Life: 100K cycles (Typical)
- Mechanical Life: 10M cycles (Typical)
- Environmental Rating: Over voltage Category II,
- Pollution Degree 2
- Relay Modes: ON/OFF or Pulse
- Pulse Timer Duration: 0.1 to 86,400 Seconds (1-day)
- Relay Connections: 1/4” Tab Terminals
Digital Inputs:
- Number of Inputs: 2
- Type: Non-Isolated
- Voltage Range: 0-5VDC
- Current: 47K Pullup
- Minimum Hold Time: 20ms
- Input Isolation: Non-Isolated
- Input Functions: Counters, Email Alerts, SNMP Traps
- Maximum Count: 32-bit
- Max Count Rate: 25Hz
- Edge Trigger: Rising, Falling or Both
Temperature Sensors:
- Maximum Number of Sensors: 16
- Type: Dallas Semiconductor DS18B20
- Temperature Range: -67°F to 257°F (-55°C to +125°C)
- Accuracy: ±0.5°C (from -10°C to +85°C)
- Sensor Functions: Monitor Temperature, Log Temperature, Email Alerts, SNMP Traps
- Humidity Type: Xytronix Model X-DTHS-P sensor
- Humidity Range: 0-100% RH
- Accuracy: ±2%
- Max Cable Length: 600 feet (180m) maximum combined cable length
Appendix F: Specications