EasyManua.ls Logo

COOLIUS Y10 - Vacuum Process; Performing System Vacuum; A;C System Charge; Charging Refrigerant and Oil

COOLIUS Y10
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31COOLIUS Y10
5.6.2 Vacuum
1. Turn COOLIUS SELECT to set the vacuum time.
Minimum: 15 min.
Maximum: 999 min.
2. Press ENTER to conrm.
3. Turn COOLIUS SELECT to set the leak test time.
Minimum: 2 min.
Maximum: 60 min.
4. Press ENTER to conrm.
5.6.3 A/C system charge
A) In case of vacuum selected.
1. Turn COOLIUS SELECT to set the Fresh oil value.
NOTE: The value indicates only the new oil added to the
drained oil.
Minimum: 0 g.
Maximum: 150 g.
2. Press ENTER to conrm.
3. Turn COOLIUS SELECT to set the refrigerant amount.
Minimum: 50 g.
4. Press ENTER to conrm.
B) In case of vacuum not selected.
C) In case of A/C system charge.
5. Turn COOLIUS SELECT to set (usually HP).
HP-PORT” / “LP-PORT” / “HP/LP PORT”
6. Press ENTER to conrm.
7. Press START key to conrm.
The equipment performs all the process selected.
5.6.4 A/C pressure test
This procedure allows to check the A/C system (pressures) without recovering refrigerant from the system.
1. Press ENTER to conrm.
Vacuum time
min. 20
Leak test min. _
PAG Oil ml. 10
Refrigerant
g._____
Refrigerant
g._____
Charge A/C system by
HP PORT
A/C Pressure Test


Table of Contents

Related product manuals