SAFETY FEATURES
Automatic Shut-Off: Should the flame extinguish for any reason, there is an automatic close off of the gas
supply.
Note: fans will continue to operate as normal.
Over Temperature Protection: In the event of the room fan failing, blockage of airways, or incorrect gas
installation, the gas supply will be automatically closed off to prevent the appliance over-heating.
Record the following information in the space provided.
Purchased from:
Name
Address
Phone No Date of purchase
Serial No of Appliance
To be completed by installer:
Name License No
Address
Phone No Date installed
Note: This appliance can only be installed by an authorized person who is responsible for its correct
operation at the time of installation.
AS/NZS 5601 Appliance Commissioning
9.2 The commissioning of an appliance shall take full account of special design features, the manufacturer’s
instructions and the appliance safety requirements.
9.3 The commissioning of an appliance shall include all of the following
(a) Compliance with clauses 2.4.2 and 2.6
(b) The appliance is to be checked to ensure safe working order.
(c) The burner of the appliance is to be lit and where necessary adjusted, in accordance with the
manufacturers instructions
(d) The consumer, where available, is to be instructed on the safe and correct operation of the appliance and
any auxiliary equipment.
(e) The appliance operating instructions are to be handed to the consumer, or if the consumer is not present,
the instructions are to be left in a suitable location on the premises.