Command 81 to 84 - Option 38
This option is now active for the following faults:
AC Fail, Anti-Mask, Aux DC, Battery Load Test Fail, Battery Missing,
Comms Fail, Jamming, Keypad Ident Fail, Line Fail (internal
communicator only), Low Battery, RF Low Battery, Supervision Fail,
Telecommand Low Battery, uCom Fail, Zone AC Fail, Zone Battery
Fault, Zone Fault, Zone Low Battery and Zone Pwr O/P.
(Plug-By/Plug-On fail no longer trigger an All Fault output.)
Command 106: - Option 0
When using option 0, the control unit does not monitor the telephone line
connected to the internal communicator. The control will still report faults on a
plug-by communicator (provided the Line Fault output from the communicator
are connected to the control unit).
Command 131:
Various new reports have been added to command 131. The table below
shows the reports now available in full, with new or changed entries
underlined.
BASIC
Event SIA Code CID Code
ALARM CONFIRM BV 139
BURG BA 130
BURG RESTORE BR 130‡
DURESS HA 121
DURESS RESTORE HH 121‡
EXIT TIMEOUT EA -
EXPANDER TAMPER TA 137
EXPANDER TAMPER RESTORE TR 137‡
FIRE FA 110
FIRE RESTORE FR 110‡
FORBI INTERFACE TAMPER TA 137
FORBI INTERFACE TAMPER RESTORE TR 137‡
FORBI LOOP TAMPER TA 137
FORBI LOOP TAMPER RESTORE TR 137‡
FORBI TAMPER TA 137
FORBI TAMPER RESTORE TR 137‡
GLOBAL TAMPER TA 137
GLOBAL TAMPER RESTORE TR 137‡
KEYBOX OPEN BA 150
KEYBOX CLOSED BR 150‡