Regen Resistor Sizing and Configuration Xenus Regeneration Guide
14 Copley Controls Corp.
A.2: Configuring a Custom Regen Resistor
A.2.1: Regen Configuration Objective and Warning
Configure the amplifier to operate properly with the custom resistor.
Incorrect values may damage amplifier or external regen resistor.
!
WARNING
For the I
2
T algorithms to work correctly, the values entered in the following steps
must be correct. Damage to the external regen resistor may result from incorrect
values entered. Damage to the amplifier may result if an incorrect resistance value is
entered.
Failure to heed this warning can cause equipment damage.
A.2.2: Regen Configuration Instructions
A.2.2.1 On the Main screen, click Configure Regen ( ) to open the Regen Resistor
screen.
A.2.2.2 Select Custom Resistor and then click Configure to open the Custom Regen
Configuration screen.
A.2.2.3 Enter a Resistance within the range described on the screen. Click Next for Step 2.