EasyManua.ls Logo

Copley Controls Xenus XTL Series - Page 23

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copley Controls, 20 Dan Road, Canton, MA 02021, USA Tel: 781-828-8090 Fax: 781-828-6547
Tech Support: E-mail: sales@copleycontrols.com, Internet: http://www.copleycontrols.com Page 23 of 28
Xenus XTL
RoHS
Resolver
DIGITAL SERVO DRIVE
for BRUSHLESS/BRUSH MOTORS
Copley
Controls
Corp.
PIN SIGNAL PIN SIGNAL PIN SIGNAL
1 Frame Gnd 6 Frame Gnd 11 Frame Gnd
2 Ref(-) Output R2 7 Sin(-) Input S1 12 Cos(-) Input S4
3 Ref(+) Output R1 8 Sin(+) Input S3 13 Cos(+) input S2
4 N.C. 9 N.C. 14 N.C.
5 Signal Gnd 10 [IN5] Motemp 15 Signal Gnd
PIN SIGNAL PIN SIGNAL PIN SIGNAL
1 Frame Gnd 10 [IN6] HS 19 Signal Gnd
2 Ref(-) 11 [IN7] HS 20 +5 Vdc (Note 1)
3 Ref(+) 12 [IN8] HS 21 Multi Encoder /X
4 [IN1] Enable 13 [IN9] HS 22 Multi Encoder X
5 [IN2] GP 14 [IN10] HS 23 Multi Encoder /B
6 [IN3] GP 15 Signal Gnd 24 Multi Encoder B
7 [IN4] GP 16 [OUT1] 25 Multi Encoder /A
8 [IN11] GP 17 [OUT2] 26 Multi Encoder A
9 [IN12] GP 18 [OUT3]
NOTES:
1. The total current drawn from the +5 Vdc output cannot exceed 400 mA
Pin Signal
6 No connect
5 TxD Output
4 Ground
3 Ground
2 RxD Input
1 No connect
Pin Signal
1 CAN_H
2 CAN_L
3 CAN_GND
4 No connection
5 No connection
6 (CAN_SHLD)
7 CAN_GND
8 (CAN_V+)
J8 MOTOR FEEDBACK
J7 CONTROL SIGNALS
J6 CAN BUS
J5 RS-232 (DTE)
ISOLATED CIRCUIT
Notes:
1. CAN circuits are opto-isolated from drive circuits.
2. CAN_GND connects to drive Signal Ground.
3. CAN_SHLD and CAN_V+ are wired-thru on both
J6 connectors and have no connection to the drive.
J5 CABLE CONNECTOR:
RJ-11 style, male, 6 position
Cable: 6-conductor modular type
J6 CABLE CONNECTOR:
RJ-45 style, male, 8 position
Cable: 8-conductor modular type
J7 CABLE CONNECTOR:
High-Density D-Sub, 26 Position, Male
J8 CABLE CONNECTOR:
High-Density D-Sub, 15 Position, Male

Related product manuals