8.2 Hardware Error
Symptom
Diagnostic Analysis
Reboot the machine
without error message
1. If power went off from FY-400 temperature
controller, please check the setting of FY-400
or replace a new one for a trial.
Incorrect temperature
displayed on the FY-400
temperature controller
1. Please replace over-temperature sensor if
malfunction.
2. Please replace FY-400 temperature controller
if malfunction.
Incorrect temperature
displayed on the HMI
1. Please replace Rotating connector inserter
set assembly (male) if malfunction.
2. Please replace Rotating connector inner race
assembly (female) if malfunction.
3. Please replace temperature sensor if
malfunction.
The cooling blower is not
working properly.
1. Please replace Relay-1 if malfunction.
2. Please replace Blower if malfunction.
The temperature can’t be
risen while running the
dyeing program.
1. Please replace FY-400 temperature controller
if malfunction.
2. Please replace Relay-2 if malfunction.
3. Please replace SSR if malfunction.
4. Please replace DTC-1000 if malfunction.
5. Please replace PLC if malfunction.
6. Please replace Heating module if malfunction.
HMI is out of order
1. Please replace HMI if malfunction.