1. Remove Needle following steps 1-3 from
previous section: “Thoroughly Cleaning the
System.”
2. Soak Needle in very warm water for ve
minutes.
3. Insert Needle Clearing Brush into top of
Needle and twist to release particles.
Remove Brush. Repeat as needed.
4. Submerge open end of Needle Clearing
Tool in cup of warm, clean water. Pull
plunger to draw water into Tool.
5. Insert Needle into open end of Tool until
fully seated.
6. Press plunger quickly to push water
through Needle.
7. Reassemble System following steps
6-9 from previous section: “Thoroughly
Cleaning the System.”
CLEARING THE NEEDLE
3
2
4
5
6
NOTE: Repeat until Needle is clear.
1. Flip Handle up and twist quarter turn
counter-clockwise. Pull up to remove Handle
and Spout.
2. Pull Needle by grip, straight up and out of
System.
3. Safely save or discard Needle.
4. Move Clamp to up position. Insert Needle
into needle well until seated. Needle is
keyed to only t one way.
5. Place Handle over needle well, and twist
quarter turn clockwise into place. Return
Clamp to down position.
CHANGING THE NEEDLE