Turning On the Carbonator Pump Block
Release air from the connected carbonator bowl by pulling the safety valve several times for about
2 seconds. Check the flow pressure in it. Standard value: 2.-3 bar.
Fill the python and purge the installation at the valve.
The carbonator pump switches on automatically and fills the carbonator bowl. The carbonator pump
switches off when the water has reached its highest level in the carbonator container.
Turning On the Still Water Pump Block
Release air from the python by opening the connected valves. Check the flow pressure in it. Standard
value: 2-3 bar.
The carbonator pump switches on automatically when the water pressure is lower as the switch on
pressure at the pressure switch and switch off whenn the switch off pressure is areached.
End of Operation
It is imperative that the CO
2
cylinder and water line be turned off each time operation is ended.
Daily Inspection
Check whether carbon dioxide and water lines are open. Working with closed water feed lines
results in draining of the python and the carbonator container.
Check the soda- and stillwater lines for leaks. Only a visual inspection is possible. If liquid escapes, call a
service technician.
Check the CO
2
lines for leaks by closing valve on the CO
2
cylinder. The inlet pressure indicated on the
pressure regulator should not drop. If it does, call a service technician immediately. Do not forget to re-
open the CO
2
cylinder valve afterwards.
Putting out of Service
Perform the following steps in case of protracted standstill periods:
Close the CO
2
-cylinder, the CO
2
-stopcocks on pressure regulators and the
water feed line. Pull the mains plug out of socket outlet with earthing contact.
Have the device cleaned and emptied.
Only trained specialists are carry out this procedure.