Balance Carbonator / Balance Karbonator
Manual operation / Gebrauchsanweisung
Carbonator/Karbonator HS/HK
Seite
14
Cornelius Deutschland GmbH
Document no/ Dokumenten-Nr.: TD22022600ML
Version A, 11.05.2020, Index 0
Installation Check List
You can use this check list to review the installation of the device. Fill out the check list and keep it with the
operating instructions.
Part number of the device:
Serial number of the device:
Installation site:
Installation date:
Installed by:
Settings:
Target Actual
Water flow pressure
2-3 bar
Outlet pressure of pump
HK 11 bar
HS 12 bar
CO pressure:
5,5 bar
2
CO volume at 4° C:
2
4,0 vol. %
Filling time of carbonator:
approx. 5 sec.