EasyManua.ls Logo

Cosel PBA300F - Expected Life and Warranty

Cosel PBA300F
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
¿
PBA1500F
¡
Input Voltage Derating Curve
Input voltage derating curve is shown in Fig.5.4.
5.3 Expected Life and Warranty
¡
Expected Life
Please see the following tables for expected life.
¿
PBA10F, PBA15F, PBW15F, PBA30F,
PBW30F, PBA50F, PBW50F, PBA75F,
PBA100F and PBA150F
¿
PBA300F, PAB600F, PBA1000F and PBA1500F
*
Values with
*
are based on the assumption that fan maintenance
will be properly done.
¿
PBA300F, PAB600F, PBA1000F and PBA1500F
¡
Fans should be exchanged on a regular basis because their life
expectancy (R (t) = 90%) vary depending on use conditions as
shown in Fig.5.5. Please see ”Optional Parts” for details about
fan units.
¡
Warranty
¿
PBA10F, PBA15F, PBW15F, PBA30F,
PBW30F, PBA50F, PBW50F, PBA75F,
PBA100F and PBA150F
¿
PBA300F, PAB600F, PBA1000F and PBA1500F
¡
The warranty period is 5 years if a power supply is used within a
derating curve.
Unit type
Instruction Manual
A-40
PB
Unit type
Instruction Manual
A-41
PB
Fig.5.3 Ambient temperature derating curve
Ambient temperature[
C
]
Load factor
[%]
80
70
80
90
100
30
40
50
60
70
71C
0
10
20
30 40 50 60- 20 - 10 200 10
Fig.5.5 Life expectancy of fan
Fig.5.4 Input voltage derating curve
[AC V]
at AC100V
[%]
100
80
85 95
Load
Ambient temperature[
C
]
[H]
Life expectancy of fan
4030 50 60 70 80
10,000
100,000
500,000
Mounting
Method
Annual Average of
Ambient Temperatures
Load Factor
50% 100%
A
Ta = 30
C
or less 10 years or more 10 years or more
Ta = 40
C
10 years or more 6 years
Ta = 50
C
5 years 3 years
B and C
Ta = 20
C
or less 10 years or more 10 years or more
Ta = 30
C
10 years or more 6 years
Ta = 40
C
5 years 3 years
Annual Average of Ambient
Temperatures
Load Factor
50% 100%
All Mounting
Methods
Ta = 40
C
or less 7 years
*
7 years
*
Ta = 50
C
6 years
*
5 years
Mounting
Method
Annual Average of
Ambient Temperatures
Load Factor
50% 100%
A
Ta = 40
C
or less 5 years 5 years
Ta = 50
C
5 years 3 years
B and C
Ta = 30
C
or less 5 years 5 years
Ta = 40
C
5 years 3 years