19
WARNING
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
1. Remove shipping materials, tape and film from the cooktop. Do not dispose
of anything until the installation is complete.
2. Set aside the surface burners and grates if they are not pre-installed.
GAS SUPPLY PRESSURE TESTING
Gas supply pressure for testing regulator must be at least 1" (2.5 cm) water
column pressure above the manifold pressure shown on the model/serial
rating plate.
Line pressure testing above 0.5 psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test
pressures in excess of 0.5 psi (3.5 kPa).
Line pressure testing at 0.5 psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
INSTALLATION INSTRUCTIONS
IMPORTANT: This appliance shall be installed only by authorized persons and
in accordance with the manufacturer's installation instructions, local gas
fitting regulations, municipal building codes, electrical wiring regulations,
local water supply regulations.
UNPACK COOKTOP