6. The LED displays
Display Charge setting Note
STANDBY Charging has not commenced Connection error, no charging
Setting 1, low charge Setting 1 (14.4 V/0.8 A)
Setting 2, high charge Setting 2 (14.4 V/4A)
Setting 3, high charge Setting 3 (14.7 V/4A)
Connection error Incorrect polarity, check
Charging Charging commenced
Conservation charging Battery fully charged
7. Care and maintenance
Cleaning: Removeplug from socket and wipe thedevice with asoft cloth and possibly
amild cleaning solution. Neveruse abrasive cleaners or solvents.
8. Disposal
When you dispose of theproduct it should be done in accordance with local regulations.
Ifyou are unsure of how to proceed, please contact thelocal authorities.
9. Specifications
Power supply 220–240 V AC, 50/60Hz
Effect 0.7 A RMS (65 W)
Discharging < 5 mA (not connected to 230 V AC)
Max voltage charge 14.4 V (±0.25 V) or 14.7 V (±0.25 V)
Charging 4.0 A (±10 %) or 0.8 A (±10 %)
Ripple 150 mV (max)
Battery types 12 V chargeable lead batteries with capacity 1.2 Ah to 120Ah
Sealing IP65
Noise < 50 dB (test at distance of 500 mm)
Dimensions 180×60×45mm
Weight 0.5kg