5. If theoil level is low add more oil. SAE 10W-30 engine oilfor
4-stroke engines is recommended for normal use (-5–25 °C).
Theoil should have anAPI service class rating of at leastSJ.
Refuelling
1. Makesure that thegenerator is flat and level and in awell-ventilated place. Unscrew thefuel cap (2).
2. Onlyuse fresh, clean petrol with anoctane rating of at least 95 and containing no more than 10 % ethanol. Theuse of
fuel with acontent of ethanol higher than 10 % could lead to engine damage which is not covered by theguarantee.
3. Screwthefuel cap back on, close theair vent (1) if thegenerator is not to be used straight away.
4. Wipeup any fuel spills immediately.
Starting the engine (cold start)
Thegenerator should be placed on afirm, flat surface with good ventilation and at least 1 metre away from building walls
and ceilings.
Note: Thegenerator engine cooling air inlet vents are located on theunderside of thegenerator. Thegenerator must not be
placed on any soft material which could block theair inlets and cause theengine to overheat.
Operating instructions
Preparations
Check the oil level before switching the generator on
1. Removethescrew (18) fastening themaintenance cover (19) (the big cover next to thestarter handle).
2. Make sure that thegenerator is on aflat and level surface. Removetheoil filler cap (7) and wipe thedipstick clean.
3. Fully insert thedipstick into thefiller neck without screwing thecap back on.
4. Remove thedipstick and read theoil level. Thereis aminimum level mark about 1 cm up from thebottom of thedipstick.
Thedipstick hole is also theoil filler neck. Theoil level should be between themark on thedipstick and thebottom of
thefiller bottom of thethread on theoil filler neck.
Upperlimit
1. Open thefuel tank cap vent by turning it clockwise to
theON position.