6
SPECIFICATIONS
(CONT’D)
SmartAir Sensor Specications
Air Quality Factor Measurement Accuracy
Minimum Time
To Acquire
Accurate Data*
Values Displayed
In App
Minimum Maximum
Temperature Temperature ±2.3 ºF (±1.3 ºC)
Immediate
32F (0C) 122F (50C)
Pressure Building Pressure
±0.100 in.WC
(±0.25 hPa)
120 in. WC
(300 hPa)
441 in. WC
(1100 hPa)
DP
Dew Point
Temperature
±2.3º F (± 1.3 ºC)
± 5% Of Reading
32F (0C) 122F (50C)
rH Relative Humidity ±5% of Reading 10% 95%
Indoor Comfort Zone
(Heating/Cooling
Season)
Temperature &
Humidity
+/- 2.3F (+/- 1.3C),
+/-5% of Reading
61F (16C) &
10% r.H.
93F (34C) &
95% r.H.
tVOC’s
Total Volatile Organic
Compounds
±(50 ppb + 15%)
5 Minutes To 60
Minutes
0 ppb 5,000 ppb**
CO
2
Carbon Dioxide
± (100 ppm +3% Of
Reading)
3 Minutes 0 ppm 5,000 ppm
PM
2.5
Fine Particulate
Matter
± 25ug/m3 for < 100
ug/m3;
±25% for > 100ug/m3
Immediate
0 ug 400 ug
PM
10
Particulate Matter 0 ug 600 ug
* After being powered ON. If stored in temperature extremes, let SmartAir adjust (unplugged) to indoor temperature for 6~8 hours.
** Accuracy spec applies up to 600 ppb. See Quick Start Guide or Owner’s Manual for additional use instructions.