7
SPECIFICATIONS
Function Range Resolution Accuracy
200mV 0.1mV
2000mV 1mV
20V 0.01V
200V 0.1V
DC Voltage
(V DC)
600V 1V
±(0.5% reading + 2 digits)
200V 0.1V AC Voltage
(V AC)
600V 1V
±(1.5% reading + 5 digits
(50/60Hz)
200mA
100µA ±(1.2% reading + 2 digits)
DC Current
(A DC)
10A 10mA
±(2.0% reading + 2 digits)
200mA
100µA ±(1.8% reading + 5 digits)
AC Current
(A AC)
10A 10mA
±(3.0% reading + 5 digits)
200Ω 0.1Ω
2000Ω 1Ω
20kΩ 0.01kΩ
200kΩ 0.1kΩ
±(0.8% reading + 2 digits)
Resistance
2000kΩ 1kΩ ±(1.0% reading + 2 digits)
9V 10mV Battery Test
1.5V 10mV
±(1.0% reading + 2 digits)
NOTE: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital converter.
NOTE: Accuracy is stated at 65
o
F to 83
o
F (18
o
C to 28
o
C) and less than
75% RH.