9
SPECIFICATIONS
Diode Test Test current of 0.6mA maximum, open
circuit voltage 1.5V DC typical
Continuity Check Audible signal will sound if the resistance
is less than approximately <30
Temperature sensor Requires type K thermocouple
Input Impedance 10M (V AC/DC)
Display 3999 count LCD
Overrange “OL” is displayed
Polarity Automatic (no indication for positive
polarity); Minus (-) sign for negative
polarity.
Measurement Rate 3 times per second, nominal
Low Battery is displayed if battery voltage
drops below operating voltage
Batteries Requires (2) AAA batteries
Fuses mA range; 250mA/250V fast blow
10A range, no protection
Operating Temp 32
o
F to 104
o
F (0
o
C to 40
o
C)
Storage Temp -4
o
F to 140
o
F (-20
o
C to 60
o
C)
Relative Humidity Maximum relative humidity 80% for
temperatures up to 31°C decreasing
linearly to 50% relative humidity at 40°C.
Operating Altitude 7000ft (2000 meters) maximum
Weight 5.4 oz. (153g).
Size 5.43x 2.83” x 1.5(138mm x 72mm x
38mm)
Approvals UL, CE
Safety This meter is intended for indoor use and
protected, against the users, by double
insulation per EN61010-1 and IEC61010-
1 2nd Edition (2001) to CAT II 600V;
Pollution Degree 2. The meter also meets
UL 61010-1, Second Edition (2004),
CAN/CSA C22.2 No. 61010-1, Second
Edition (2004), and UL 61010B-2-031,
First Edition (2003)